Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. enferm. Inst. Mex. Seguro Soc ; 28(2): 102-110, Abr-Jun. 2020. graf
Article in Spanish | LILACS, BDENF | ID: biblio-1121733

ABSTRACT

Introducción: la autoevaluacíón permite un monitoreo continuo del quehacer profesional para perfeccionar la competencia clínica. Por tal motivo se diseñó y validó un instrumento de autoevaluacíón de enfermería para la fase de valoración de mujeres con preeclampsia. Método: la validez de contenido se realizó con tres expertos en dos rondas. La investigación se llevó a cabo en los servicios de Gineco-Obstetricia, Unidad Toco Quirúrgica, Unidad de Cuidados Intensivos y Quirófano en un hospital de zona con 40 enfermeras. La consistencia interna se identificó con el índice de Alfa de Cronbach y se calculó la prueba de Spearman-Brown para identificar la correlación intra dimensiones del instrumento. Resultados: se obtuvo una validez de contenido con Alfa de Cronbach en la prueba piloto de 0.977 y en la aplicación final de 0.923; así como correlaciones estadísticamente significativas entre las dimensiones del instrumento. Conclusión: el instrumento permite un marco de referencia en autoevaluacíón diagnóstica de enfermería en la valoración en mujeres con preeclampsia. Se considera práctico, tiene propiedades psicométricas aceptables de consistencia interna y confiabilidad.


Introduction: The self-assessment allows continuous monitoring of professional work to improve clinical competence. For this reason, a nursing self-assessment instrument was designed and validated for the assessment phase of women with pre-eclampsia. Method: Content validity was performed with three experts in two rounds. The research was carried out in the Services of Gynecology-Obstetrics, Toco Surgical Unit, Intensive Care Unit and Operating Room ¡n an area hospital with 40 nurses. Internal consistency was identified with the Cronbach's Alpha índex and the Spearman-Brown test was calculated to identify the intra-dimensional correlation of the instrument. Results: Content validity was obtained with Cronbach's Alpha in the pilot test of 0.977 and in the final application of 0.907; as well as statistically significant correlations between instrument dimensions. Conclusión: The instrument allows a frame of reference in diagnostic nursing self-assessment in the assessment phase in women with preeclampsia. It is considered practical, it has acceptable psychometric properties of internal consistency and reliability.


Subject(s)
Humans , Female , Pregnancy , Pre-Eclampsia , Reproducibility of Results , Nursing , Clinical Competence , Expert Testimony , Diagnostic Self Evaluation , Hospitals, Public , Mexico
SELECTION OF CITATIONS
SEARCH DETAIL